Industrial and Commercial Exhaust Fans
Triangle wall exhaust fans that move heat, humidity and stale air out of a building.

Every fan on this page mounts in a wall and pulls air out of the building: heat from a shop floor, humidity from a greenhouse, stale air from a warehouse. They come from Triangle Engineering, in sizes from 12 to 48 inches and rated airflow from 1,580 to 28,300 CFM.
There are five Triangle lines here. The GPX general purpose fans (12 to 30 inch, 115V) have a built-in shutter that opens when the fan starts, and they ship assembled. The V and VI lines are belt drive industrial fans, and the VI adds a heavy gauge galvanized housing. Most of the belt drive models have an automatic belt tensioner, which Triangle says reduces maintenance and extends belt and motor life. The VIK packages are heavy duty belt drive fans that arrive with shutters and guards installed. The FHIR fans are true reversible: one fan can exhaust air or bring fresh air in, and the reversing switch comes standard.
Motors run on single-phase 115V, 230V or 115/230V, or three-phase 230/460V. Eleven models have hazardous location motors (see the questions below).
To size a fan, start with the building's volume, or let the Fan Finder do the math. Every exhaust fan here is quoted rather than sold at a posted price. Send us the building size and what the fan needs to do, and a fan specialist confirms the model before you order.
Exhaust Fans Products
Showing 24 of 95 products
Full product list
- Triangle VI3613T-X 36" 1-Speed 1/2 HP 3-Phase Industrial Exhaust Fan
- Triangle VI3613T-U 36" 1 Speed 1/2 HP 115/230V Industrial Exhaust Fan
- Triangle VI3613HL-X: 36" 1 Speed 1/2 HP Hazardous Exhaust Fan
- Triangle VI3613HL-U 36" 1 Speed 1/2 HP 115/230V Industrial Exhaust Fan
- Triangle VI3014-X 30" 1-Speed 3/4 HP Industrial Exhaust Fan
- Triangle VI3014-U: 30" 1 Speed 3/4 HP Belt Drive Industrial Exhaust Fan
- Triangle VI3014T-X 30" 1 Speed 3/4 HP 230/460V Industrial Exhaust Fan
- Triangle VI3014T-U 30" 1 Speed 3/4 HP 115/230V Industrial Exhaust Fan
- Triangle VI3014HL-X 30" 1 Speed 3/4 HP Industrial Exhaust Fan 230/460V
- Triangle 30" 1 Speed 3/4 HP HL Exhaust Fan 115/230V VI3014HL-U
- Triangle 30" 1 Speed 1/2 HP 3-Phase Belt Drive Exhaust Fan VI3013-X
- Triangle VI3013-W 30" 1-Speed 1/2 HP 230V Industrial Exhaust Fan
- Triangle VI3013-V 30" 1 Speed 1/2 HP 115V Belt Drive Exhaust Fan
- Triangle VI3013T-X 30" 1 Speed 1/2 HP 230/460V Industrial Exhaust Fan
- Triangle VI3013T-U 30" 1 Speed 1/2 HP Industrial Exhaust Fan
- Triangle 30" 1-Speed 1/2 HP 3-Phase Hazardous Exhaust Fan VI3013HL-X
- Triangle 30" 1-Speed 1/2 HP Belt Drive Hazardous Exhaust Fan VI3013HL-U
- Triangle 30" 1 Speed 1/3 HP 3-Phase Belt Drive Exhaust Fan VI3012-X
- Triangle VI3012-W 30" 1 Speed 1/3 HP 230V Belt Drive Exhaust Fan
- Triangle VI3012-V 30" 1-Speed 1/3 HP 115V Belt Drive Exhaust Fan
- Triangle 30" 1-Speed 1/3 HP 3-Phase Industrial Exhaust Fan VI3012T-X
- Triangle VI3012T-U 30" 1 Speed 1/3 HP Industrial Exhaust Fan 115/230V
- Triangle VI2413-X 24" 1-Speed 1/2 HP 3-Phase Industrial Exhaust Fan
- Triangle 24" 1-Speed 1/2 HP 230V Industrial Exhaust Fan VI2413-W
- Triangle VI2413-V: 24" 1 Speed 1/2 HP 115V Belt Drive Exhaust Fan
- Triangle VI2413T-X 24" 1-Spd 1/2 HP 230/460V 3-Ph Industrial Fan
- Triangle VI2413T-U 24" 1-Speed 1/2 HP Industrial Exhaust Fan 115/230V
- Triangle VI2413HL-X 24" 1-Speed 1/2 HP HazLoc Exhaust Fan 230/460V
- Triangle 24" 1-Speed 1/2 HP Hazardous Location Industrial Exhaust Fan VI2413HL-U
- Triangle VI2412-X 24" 1-Speed 1/3 HP Industrial Exhaust Fan 230/460V
- Triangle VI2412-V: 24" 1-Speed 1/3 HP 115V Industrial Exhaust Fan
- Triangle 48" 1 Speed 3/4 HP 230/460V V4814-X Exhaust Fan
- Triangle V4814-U 48" 1 Speed 3/4 HP 115/230V Commercial Exhaust Fan
- Triangle 48" 1 Speed 1/2 HP 230/460V 3-Ph Commercial Exhaust Fan V4813-X
- Triangle V4813-V 48" 1 Speed 1/2 HP 115V Belt Drive Exhaust Fan
- Triangle 48" 1 Speed 1/2 HP Commercial Exhaust Fan 115/230V | V4813T-U
- Triangle 42" 1-Speed 3/4 HP 230/460V Commercial Exhaust Fan V4214-X
- Triangle V4214-U 42" 1 Speed 3/4 HP Belt Drive Commercial Exhaust Fan
- Triangle 42" 1 Speed 1/2 HP 3-Phase Commercial Exhaust Fan V4213-X
- Triangle V4213-V 42" 1-Speed 1/2 HP Commercial Exhaust Fan 115V
- Triangle V4213T-W 42" 1-Speed 1/2 HP 230V Commercial Exhaust Fan
- Triangle V4213T-U 42" 1-Speed 1/2HP 115/230V Belt Drive Exhaust Fan
- Triangle V3614-X: 36" 1 Speed 3/4 HP 230/460V 3-Phase Exhaust Fan
- Triangle V3614-U 36" 1-Speed 3/4 HP 115/230V Commercial Exhaust Fan
- Triangle V3613-X 36" 1-Speed 1/2 HP 230/460V 3-Phase Exhaust Fan
- Triangle V3613-V 36" 1 Speed 1/2 HP 115V Belt Drive Exhaust Fan
- Triangle V3613T-U 36" 1-Speed 1/2 HP 115/230V Commercial Exhaust Fan
- Triangle V3013-X 30" 1 Speed 1/2 HP 230/460V 3-Ph Exhaust Fan
- Triangle V3013-V 30" 1 Speed 1/2 HP 115V Belt Drive Exhaust Fan
- Triangle V3013T-X: 30" 1 Speed 1/2 HP 3-Phase Commercial Exhaust Fan
- Triangle V3013T-W: 30" 1 Speed 1/2 HP 230V Belt Drive Exhaust Fan
- Triangle V3013T-U 30" 1-Speed 1/2 HP 115/230V Commercial Exhaust Fan
- Triangle V3012-V 30" 1-Speed 1/3 HP 115V Belt Drive Exhaust Fan
- Triangle V2412-V: 24" 1-Speed 1/3 HP 115V Belt Drive Exhaust Fan
- Triangle GPX3013 30" 1-Speed 1/2 HP 115V Exhaust Fan, Direct Drive
- Triangle GPX2413: 24" 1-Speed 1/2 HP 115V Direct Drive Exhaust Fan
- Triangle 20" 1 Speed 1/4 HP 115V Exhaust Fan GPX2011 (70 chars)
- Triangle 16" GPX1611 General Purpose Exhaust Fan, 1 Speed, 1/4 HP, 115V
- Triangle GPX1210: 12" 1 Speed 1/6 HP 115V Direct Drive Exhaust Fan
- Triangle 48" 1-Speed 3 HP Reversible Direct Drive Exhaust Fan | 230/460V
- Triangle FHIR4818T-X-BD 48" 1 Speed 3 HP 3-Phase Reversible Exhaust Fan
- Triangle 48" 3 HP 1-Speed Reversible Exhaust Fan 115/230V FHIR4818T-U-BD
- Triangle 48" 1-Speed 2 HP 3-Phase Reversible Direct Drive Exhaust Fan
- Triangle 48" Reversible Exhaust Fan, 1 Speed, 2 HP, 230/460V (FHIR4817T-X-BD)
- Triangle 48" Reversible Exhaust Fan, 1-Speed, 2HP, 115/230V, FHIR4817T-U-DD
- Triangle 48" 1-Speed 2HP 115/230V Belt Drive Reversible Exhaust Fan
- Triangle 48" 1-Spd 1HP 230/460V 3Ph Direct Drive Reversible Exhaust Fan
- Triangle 48" 1-Speed 1 HP 230/460V Reversible Belt Drive Exhaust Fan
- Triangle FHIR4815T-U-DD 48" 1-Speed 1 HP 115/230V Exhaust Fan
- Triangle 48" Reversible Exhaust Fan, 1 HP, 1 Speed, 115/230V, FHIR4815T-U-BD
- Triangle 36" 1-Speed 2HP 230/460V 3-Ph Reversible Exhaust Fan FHIR3617T-X-DD
- Triangle 36" 1-Speed 2 HP 230/460V Reversible Exhaust Fan FHIR3617T-X-BD
- Triangle 36" 1-Speed 2HP 115/230V Reversible Exhaust Fan FHIR3617T-U-DD
- Triangle 36" 1-Speed 2HP 115/230V Reversible Exhaust Fan FHIR3617T-U-BD
- Triangle FHIR3615T-X-DD 36" 1 HP Direct Drive Reversible Exhaust Fan
- Triangle 36" 1 HP 3-Phase Reversible Exhaust Fan FHIR3615T-X-BD
- Triangle 36" 1 Speed 1 HP 115/230V Reversible Direct Drive Exhaust Fan
- Triangle 36" 1 HP 1 Speed Reversible Exhaust Fan 115/230V FHIR3615T-U-BD
- Triangle 30" 1 Speed, 2 HP, 230/460V, 3-Ph Reversible Exhaust Fan FHIR3017T-X-DD
- Triangle 30" 1-Speed 2 HP Reversible Exhaust Fan FHIR3017T-X-BD
- Triangle 30" 1-Speed 2 HP Reversible Direct Drive Exhaust Fan (115/230V)
- Triangle 30" 1 Speed 2 HP Reversible Exhaust Fan 115/230V (FHIR3017T-U-BD)
- Triangle 30" 1HP 3-Phase Reversible Direct Drive Exhaust Fan FHIR3015T
- Triangle 30" 1 HP 3-Phase Reversible Exhaust Fan FHIR3015T-X-BD
- Triangle 30" 1 Speed 1 HP Reversible Exhaust Fan 115/230V FHIR3015T-U-DD
- Triangle 30" 1 Speed 1 HP Reversible Exhaust Fan 115/230V FHIR3015T-U-BD
- Triangle VIK4818-X 48" Belt Drive Exhaust Fan – High-Volume Ventilation
- Triangle VIK4815HL-U 48" Hazardous Exhaust Fan – Safe High-Performance Venting
- Triangle VIK4814-X 48" ODP Exhaust Fan – 3-Phase Power
- Triangle VIK4814-U 48" ODP Exhaust Fan – Efficient 1-Phase Ventilation
- Triangle VIK4814T-X 48" TEFC Exhaust Fan – 3-Phase Durability
- Triangle VIK4814T-U 48" TEFC Exhaust Fan – Durable 1-Phase Performance
- Triangle VIK4814HL-X 48" Hazardous Exhaust Fan – 3-Phase Safety
- Triangle VIK4814HL-U 48" Hazardous Exhaust Fan – Safe High-Performance Venting
- Triangle VIK4218-X 42" Belt Drive Exhaust Fan – Powerful Industrial Ventilation
| Line | Sizes | Motor | Rated airflow | Drive | Notes |
|---|---|---|---|---|---|
| GPX general purpose | 12 to 30 in | 1/6 to 1/2 HP | 1,580 to 6,800 CFM | Direct | Built-in automatic shutter; 115V; ships assembled |
| V industrial | 24 to 48 in | 1/3 to 3/4 HP | 3,920 to 18,100 CFM | Belt | Automatic belt tensioner |
| VI heavy duty | 24 to 36 in | 1/3 to 3/4 HP | 4,190 to 10,800 CFM | Belt | Heavy gauge galvanized housing; 8 hazardous location models |
| VIK package | 42 to 48 in | 3/4 to 3 HP | 19,100 to 25,000 CFM | Belt | Shutters and guards installed; 3 hazardous location models |
| FHIR reversible | 30 to 48 in | 1 to 3 HP | 8,400 to 28,300 CFM | Belt or direct | Exhausts or supplies from one fan; reversing switch included |
Rated airflow is Triangle's free-air figure, at 0 inches of static pressure. Shutters, guards, screens and duct runs add resistance and lower it. Triangle's catalog lists each fan's airflow at 0.125 and 0.25 inch as well: its 24-inch V2412, for example, drops from 3,920 CFM in free air to 2,070 CFM at 0.125 inch.
Common questions
How do I size an exhaust fan for a building?
Triangle's rule starts with the building's volume. Multiply length by width by ceiling height to get cubic feet. Then choose how often to replace all the air: every 2 to 4 minutes to cool people, 4 to 6 minutes to cool product, or 6 to 10 minutes to clear stale air. Divide the cubic feet by those minutes to get the CFM you need. In Triangle's example, a 100 by 100 foot building with a 10 foot ceiling holds 100,000 cubic feet, and a 4-minute air change calls for 25,000 CFM, from one fan or several. Climate and equipment can change the answer, so treat it as a starting point. The Fan Finder uses the same rule.
Belt drive or direct drive?
Both are here. The GPX line and the direct drive FHIR models have no belt to adjust or replace. The V, VI and VIK lines and the belt drive FHIR models do, and most of them have an automatic tensioner that Triangle says reduces maintenance and extends belt and motor life. Our oven exhaust job story walks through one replacement that moved from belt to direct drive.
What is a hazardous location exhaust fan?
The HL models have an explosion-proof motor and spark-resistant aluminum blades. Triangle rates its belt drive HL motors for Class I, Division 1, Group D and Class II, Groups F and G. Triangle also says those parts alone don't make the installed fan suitable for a hazardous atmosphere. The application and wiring must meet local, state and national codes and be done by a qualified electrician, and the fans shouldn't go where paint residue can build up on the motor or blades. Triangle builds HL models to order, and they can't be returned.
Can one fan both exhaust and supply air?
The FHIR models can. They're true reversible wall fans with a two-way venturi and blades, which Triangle says avoids the airflow loss of ordinary reversible fans. A reversing switch comes standard. They come in 30, 36 and 48 inch, belt or direct drive.
Do these fans come with shutters?
The GPX fans have a built-in shutter that opens and closes as the fan turns on and off. The VIK packages ship with shutters and guards installed. For the other lines, shutters and fan guards are on our Industrial Shutters & Accessories page.
I'm replacing a Triangle fan. How do I read the model number?
Start with the nameplate. A Triangle number reads in order: series (V, VI, VIK, FHIR), blade diameter in inches, number of speeds, a horsepower code (3 is 1/2 HP, 5 is 1 HP), then a voltage letter. A "T" before the voltage letter means an enclosed motor, "HL" means a hazardous location motor, and an "R" in front means a supply fan. The voltage letters are U for 115/230V single-phase, V for 115V only, W for 230V only, X for 230/460V three-phase, Y for 230V three-phase and Z for 460V three-phase. So a VI3013T-X is a 30-inch, one-speed, 1/2 HP heavy duty fan with an enclosed motor on 230/460V three-phase. Include the old fan's nameplate details when you ask for a quote.
Features
Key Benefits
12 to 48 inch, 1,580 to 28,300 CFM
Belt and direct drive
Shutters built in (GPX) or installed (VIK)
Reversible models for exhaust or supply
Hazardous location motors on 11 models
Applications
Perfect For
Factories
Warehouses
Workshops and garages
Gymnasiums
Greenhouses
Barns
























